Central Control Box (Part No.: 803690782)
Pre-Installation Check:
Verify component integrity (no cracks/dents) and confirm 24V DC compatibility .
:
Secure to chassis using stainless bolts . Apply thread lock.
:
Connect CAN bus cables (shielded, 22 AWG) per 11898-2. Terminate connectors.
:
Attach grounding strap (>=4mm², tinned copper) to designated terminal (resistance <=0.1Ω).
:
Power on and verify LED indicators. Test I/O signals with diagnostic tool .
:
Disconnect battery before installation. Avoid pinching cables during routing.
| 803690782 | |||
| ECB0721-DP | |||
| / | 1.6KG | ||
| 1 PC |
Chú phổ biến: 803690782 original factory centralized control box for xcmg loader, China 803690782 original factory centralized control box for xcmg loader manufacturers, factory